Embrace
Embrace
HomeContentReportBack to Website
Copyright © 2026, Ianus Technologies Ltd. All Rights Reserved|Privacy Policy|Cookie Policy

Content Library

Browse tools, standards, stakeholders, and resources for CBRN professionals.

Product / ServiceDetection, Identification and Monitoring (DIM)

SASS 2300 Wetted-Wall Air Sampler

A highly efficient, portable multi-stage wetted-wall cyclone sampler that extracts particulates and water-soluble chemical vapors from air and transfers them to a liquid phase for later detection and analysis. This user-friendly sampler has been field- tested and used at a number of facilities including subway systems, public health facilities, nuclear power plants, corporate mail rooms and poultry ranches. It has been proven to possess excellent collection properties. Our patented technology can amplify trace aerosol concentration by extending the sampling time and the fluid monitoring system will maintain a fixed liquid volume in the device that is independent of collection time, air temperature or relative humidity. It is highly automated, can be easily carried by a single person, and may operate unattended for extended time periods. The SASS 2300 is the only wet-type air sampler shown to efficiently collect virus-sized particles, and has been successfully used to detect the airborne viral pathogens that cause exotic Newcastle disease and hoof-and-mouth disease*, as well as some strains of avian flu virus. Furthermore, it was the only portable sampler technology to receive US Department of Homeland Security Certification under the US Safety Act of 2002.

EN
resrchintl.com
Product / ServicePersonal Protective Equipment (including Collective Protection)

Gas-Tight Training Suit

A training version of the Respirex fully encapsulating Type 1A - ET regular robustness gas-tight suits. The suit is manufactured in green PVC and clearly marked training suit to avoid confusion in an emergency. Training suits reproduce the features of the operational suit and are designed for multiple re-use with no testing required.

ENFRDE+3
respirex.com
Product / ServiceDetection, Identification and Monitoring (DIM)

BNS-94 Radiation Control Gate

BNS-94 RADIATION CONTROL GATE PLACES OF APPLICATION: Border stations Customs checkpoints Defense systems Nuclear facilities Metal processors OBJECTS OF INSPECTION: Train cars Trucks Ships Cargoes Hand luggage Pedestrian traffic The BNS-94 Radiation Control Gate was developed by Gamma Technical Corporation to serve as a high-sensitivity device for reconnaissance and testing natural and artificial radiation sources. The detector of the BNS-94 Radiation Control Gate is a scintillation probe with high sensitivity for gamma and neutron radiation. A patented measurement method assures background, shielding, and speed compensation in one single detector. The connected computer receives the data from the detectors in every half seconds then calculates the actual alteration from the average background level. If the difference exceeds the preset value then the alarm goes off and the event gets registered into a log file.

BGHRCS+32
gammatech.hu
Product / ServiceMedical Counter Measures

Filter-ventilation unit DFU – CRISIS

WITH FILTER CRISIS Filter-ventilation unit with DFU the state-of-the-art technology and a unique filter Solution for: hospital – infectious diseases department, hospital – postoperative care labs, epidemics and pandemics, weakened, immunity kindergartens, schools, allergy sufferers, asthmatics smog area USE: doctor´s office, waiting rooms, infectious diseases department, oncology, cystic fibrosis, asthma, COPD, specialized centers – clinics for parasitic and tropical diseases, installation of ambulances, containers, mobile laboratories, ICU units, field hospitals, CO shelters, schools, family houses, spas, sanatoriums, industrial work places, etc. TYPES OF DFU UNITS FILTER IMMUNITY allergens, pollens, bacteria, mold spores and dust, viruses SMOG hydrocarbon, smog, allergens, pollen, dust, mold, viruses CRISIS / CBRN life-threatening gases, bacteria, fallout, hydrocarbon, mold spores, odors, viruses Technical specification Power consumption max. 100 W Dimensions (inner part, outer part) 465 x 375 x 170 mm (š-v-h) Supply voltage 230 V~ / 50 Hz Air output max. 220 m3/hour. (varies by filter) Noise max. 45 dB Filtration efficiency 99.998 % Full filter optical and acoustic Overpressure signaling optical Benefits state-of-the-art technology still available only in special sectors fresh air supply to the room overpressure / underpressure high filtration efficiency low energy consumption easy to install indoors quick filter change installation without building permit Certification Certification according to ČSN EN 60335-led.3: 12 + A11: 14, ČSN EN 55014-led.4: 17, ČSN EN 61000-3-2ed.4: 15, ČSN EN 61000- 33ed.3: 14, ČSN EN 55014-2ed.2: 17. Conformity of the product according to Government Decree No. 118/2016 Coll. (2014/35 / EU), 117/2016 Coll. (2014/30 / EU). Electrotechnical Testing Institute, Prague, CZ.

CSEN
dekontacbrn.cz
Standard

ISO -- PPE for firefighters — Test methods and requirements for PPE used by firefighters who are at risk of exposure to high levels of heat and/or flame while fighting fires occurring in structures,2015

ISO 11999 specifies minimum design and performance requirements for personal protective equipment (PPE) to be used by firefighters, primarily but not solely to protect against exposure to flame and high thermal loads. To assist with choice based on user risk assessment, types and performance levels for different categories of protection are included. The scope of ISO 11999-1:2015 does not include PPE for use in high-risk fire exposures where, for example, protective clothing with reflective surface according to ISO 15538 might be more appropriate, or for use in long-term firefighting operations in high ambient temperature (for example, bush, wildland, or forest firefighting) where equipment according to ISO 16073 might be more appropriate. Similarly, ISO 11999 does not include PPE to protect against chemical and biological hazards, other than against short-term and accidental exposure while engaged in firefighting and associated activities when fighting fires occurring in structures. ISO 11999-1:2015 describes the general structure of this International Standard, sets design and performance requirements for PPE, and includes requirements for marking and manufacturer's instructions.

iso.org
Product / ServicePersonal Protective Equipment

Pyridostigmine bromide (PB) tablets

Pyridostigmine bromide (PB) is approved by the Food and Drug Administration (FDA) to be used as a pretreatment for exposure to the chemical nerve agent, soman. Common brand names: Mestinon, Regonol.

EN
cbrnetechindex.com
Product / ServicePersonal Protective Equipment (including Collective Protection)

Safety pack box – larger

Practical bag for storing the Nanologix Respira Compact half mask and up to 2 filters. The universal attachment allows you to wear the Safety Pack on your belt, vest, backpack, etc. The bag is also equipped with a set of spare mask clips, disposable gloves and a disinfectant wipe. The pack does not include the RESPIRA mask or NANO-Perfection filters. Description – black fabric box with zipper closure for storage of Nanologix Respira Compact products – Designed with practical clips that allow easy attachment to a belt – The pack comes with 1 pair of disposable latex gloves, a set of spare clips to attach the mask and a disposable disinfectant wipe. – No half mask or filters are included. Dimensions: 20 x 10 x 7 cm (height x width x depth) Weight: approx. 180 g

BGHRCS+21
dekontacbrn.cz
Product / ServiceIntegrated information management

Geographical and Environmental Database Information System (GEDIS)

Geographical and Environmental Database Information System (GEDIS) provides a set of geospatial software components. The system is designed to both model geographic data and perform spatial analysis for a variety of military and civil systems. It utilises a range of open source libraries to provide a comprehensive suite of geospatial functionality. GEDIS can be used to provide intelligence for a number of other capabilities; client applications range from dispersion and meteorological models, to sensor placement and hazard prediction systems. It also seamlessly integrates with several HASP Suite tools including the Urban Dispersion Model (UDM), Urban Subsystem (USS), Sensor Placement Tool (SPT) and Source Term Estimation (STE).

EN
riskaware.co.uk
Product / ServiceLaboratory Analysis, Trace Analysis

Micro GC System

Agilent 990 Micro GC systems are designed for gas analysis. They provide quick startup and response time even if changing measurement locations frequently. Various configuration options offer up to four channels of separation and detection. The GC can be used in the lab, on-line, or in the field. They use only 10% of the power and carrier gas compared to a conventional lab GC.

ENFR
cbrnetechindex.com
StandardTechnical Specification

Security and resilience - Crisis management - Guidelines (ISO 22361:2022)

This document provides guidance on crisis management to help organizations plan, establish, maintain, review and continually improve a strategic crisis management capability. This guidance can help any organization to identify and manage a crisis. Elements for consideration include: — context, core concepts, principles and challenges (see Clause 4); — developing an organization’s crisis management capability (see Clause 5); — crisis leadership (see Clause 6); — the decision-making challenges and complexities facing a crisis team in action (see Clause 7); — crisis communication (see Clause 8); — training, validation and learning from crises (see Clause 9). It is applicable to top management with strategic responsibilities for the delivery of a crisis management capability in any organization. It can also be used by those who operate under the direction of top management. This document acknowledges the relationship and interdependencies with various disciplines but is distinct from these topics.

standards.iteh.ai
Product / ServiceDetection, Identification and Monitoring (DIM)

Compound scintillators

Compound scintillators Material Select Radiation type Select High temperature No Mortise No Diameter 14 mm Height 1 mm The Gamma Technical Corporation offers wide range of plastic and inorganic crystal scintillator materials. Our scintillators are available with diameters between 0.25" to 5" and thicknesses up to 12". Well-type and transversely bored crystals are designed according to the costumer's wish. The container canister could have rectangular and cylindrical shapes with grooved or flanged endcaps, as well. To applications in mixed radiation field, layered (sandwich) scintillators with α, β, n and γ sensitivity are produced. Unique scintillators according to special customer requirements are also welcome. Sodium-iodide scintillators Widely known inorganic scintillator crystal material is thallium activated sodium-iodide (NaI:Tl). Its light yield in case of incident γ-photons has an average value of 39 photons/keV, which provides the reference point for other scintillators. The primary decay time has a value of 0.25 μs at room temperature. Slowly elevating the ambient temperature (max. 20 °C/hour) to avoid crystal damages due to thermal shock, NaI:Tl is able to operate even at 150°C. Sodium-iodide scintillators are commonly applied in medical, nuclear, scientific, industrial and military measurement facilities. Depending on the geometry, size, mortise and further properties, several application opportunities are available. Beside high energetic γ-particles, measurements of Röntgen and Mössbauer radiation could be also performed using especially thin crystals. Combining NaI with additional scintillating and converter materials (PVT plastic, ZnS:Ag, boronpolyester, etc.) allows the detection of other particles, such as n, α and β. Cesium-iodide scintillators Thallium and sodium doped cesium-iodide (CsI:Tl, CsI:Na) crystal detectors are almost applied for γ-ray measurements. The obtainable light yield values are 54 photons/keV and 41 photons/keV for the two subtypes. The primary decay time of scintillation with thallium and sodium doping are 1 μs and 0.6 μs. Beneficial property of monocrystalline CsI against NaI is its weaker hygroscopic material and mechanical stress standing structure. As is case of NaI crystals, CsI scintillators may be delivered with several specific geometries, sizes and constructions. BGO scintillators BGO scintillator crystals have a light yield value of ~10 photons/keV what is the about the one-fourth of the value obtained with NaI:Tl detectors. Beneficial properties of BGO are its non-hygroscopic material and its crystal structure without cleavage planes; therefore it may have several geometries and encapsulations. The primary decay time is near to the value of that of NaI crystals, 0.3 μs. BGO is one of the most stable radiation standing scintillator materials, thereby its application is also recommended for measurements in strongly irradiated test environments up to maximum 10 Gray doses. Lanthanum bromide (LaBr3:Ce) scintillators Lanthanum bromide is highly recommended scintillator crystal for measurements where high energy resolution is an important factor. Due to its fast primary decay time of 16 ns and high light yield of 160 photons/keV, LaBr3:Ce is a really suitable detector for such applications. Its material is hygroscopic, thus the proper isolating encapsulation of the crystal is necessary. Calcium-fluoride (CaF2:Eu) scintillators Calcium-fluoride is a non-hygroscopic material which is commonly applied in optics, spectroscopy, laser techniques and imaging. With europium activator it is proper scintillator for charged particle and higher energetic gamma ray detection. Its light yield for gamma particles is ~19 photons/keV and the primary decay time is at 0.9 μs. Due to its mechanically and thermally stable material, CaF2 could be prepared in several geometrical forms. PVT plastic We offer polyvinyl toluene plastic scintillators for general purposes. PVT scintillators are able to detect different radiations, such as proton, β and γ. Applying silver activated zinc-sulphide layer on the surface of the plastic scintillator it is possible to measure α-particles. Incorporation lithium-6 or boron-10 together with the zinc-sulfide layer, α-particles and secondary heavy charged nuclei after thermal neutron irradiation could be also detected. Zinc-sulphide (ZnS:Ag) scintillators Zinc-sulphide is commonly applied for α-particle detection. Incorporation lithium-6 or boron-10 together with the zinc-sulfide, α-particles and secondary heavy charged nuclei after thermal neutron irradiation could be also detected. Fast neutron detection with Zn:S scintillator is based on proton recoil effect in hydrogen rich material or it could be performed by neutron thermalization in plastic and capture of secondary charged particles.

BGHRCS+32
gammatech.hu
Product / ServiceDetection, Identification and Monitoring (DIM)

SASS 3100 Dry Air Sampler

The SASS® 3100 Smart Air Sampler System is a compact, rugged microprocessor‐controlled portable air sampler designed for use with state‐of‐ the‐art electret filter media. It is highly suited to the collection of biological and radioactive aerosols. In independent tests performed by third parties, it has out‐performed all competitors in terms of collection efficiency and suitability. The standard 44mm diameter electret filter used with the SASS 3100 samples at a maximum rate of 300 liters/minute and has a collection efficiency of 50% at an aerosol particle diameter of 0.5 microns. A second HEPA‐style electret filter that is physically interchangeable has 95%+ collection efficiency for particles greater than 0.3 microns in diameter. It has a maximum sampling rate is 49 liters/minute‐ a very high rate for a HEPA‐style filter of this size. For users interested in collecting radioactive aerosols, the HEPA‐style filter meets all key international standards for radioaerosol collection. Flow rates and sampling protocols are microprocessor controlled and may be pre‐ programmed for different types of field work using a bundled PC software package. The unit can be operated in local mode wherein the user turns the fan on and off manually or it can also be operated remotely via an RS232 serial link. For applications where run‐to‐run cross‐contamination is a serious concern, the filter mounting structure may be removed and cleaned as a separate component. The motor/rotor assembly may also be removed and the rotor cleaned. Field operation may be powered by either a primary or rechargeable battery. The primary battery provides over 24 hours of continuous operation at maximum flow, while the rechargeable battery should power the device for about 20 hours. A universal wall‐plug power supply accepting 100‐240 V AC at 50‐60 Hz is also provided.

EN
resrchintl.com
Standard

BS -- Respiratory protective devices for use against chemical, biological, radiological and nuclear (CBRN) agents Positive pressure, self-contained, open-circuit breathing apparatus. Specification,2020

This British Standard specifies requirements for positive pressure, self-contained, open-circuit breathing apparatus (SCBA) intended to be used during fire-fighting, rescue, evacuation, escape, hazard containment and decontamination, and similar activities by emergency first responders (e.g. fire, ambulance, police, and associated civilian agencies and workers) in areas containing and contaminated by chemical, biological, radiological and nuclear (CBRN) agents.

shop.standards.ie
Product / ServiceDetection, Identification and Monitoring (DIM)

pTD (portable Toxin Detector)

The portable Toxin Detector (pTD) allows the rapid, specific and sensitive identification of multiple toxins. Sampling The system is able to analyze liquid and solid samples. Sample preparation includes resuspension and filtration of sample matrices using pTD Sample Preparation Kit. Technology The detection principle is based on an electrochemical Enzyme-linked Immunosorbent Assay (ELISA) procedure. Features Parallel analysis of five toxins in less than 25 minutes, excellent sensitivities, minimal sample preparation, automated sample and data processing, portable instrument, integrated positive and negative control, integrated decontamination procedure, extendable to new threats. Device Types and Application The system is intended for on-site analysis of toxins in mobile labs and onboard vehicles. Consumables and Maintenance Recently, there are four Kits available for the pTD. 1. Sample Preparation Kit - includes all buffers and consumables necessary for two sample preparations. 2. Toxin Test Kit BWA I - detection of BoNT/A, BoNT/B, BoNT/E (all CDC Category A), ricin and SEB (both CDC Category B) (5 measurements). 3. Toxin Test Kit BWA II - detection of BoNT/A, BoNT/B, BoNT/F (all CDC Category A), ricin and SEB (both CDC Category B) (5 measurements). 4. Training Kit - detection of goat immunoglobulin G (IgG) as an analog for a proteinaceous toxin (2 measurements). 5. Washing Kit - before storage the system fluidics have to be cleaned by using this kit. All kits have to be stored at +4 to +8°C. The shelf lifetime is 6 months. No preventive maintenance is required.

EN
bruker.com
Product / ServiceDetection, Identification and Monitoring (DIM)

BNS-98L Remote Dose-Rate Transmitter

BNS-98L REMOTE DOSE-RATE TRANSMITTER PLACES OF APPLICATION Field survey Environment monitoring Vehicles UAVs FEATURES Measuring gamma radiation from natural background to catastrophe level Two fixed, one dynamic alarm thresholds Automatic data collection Easily replaceable data memory Data reader with USB port Location by GPS, continuous connection to PC Optional meteo sensors High reliability Military construction The BNS-98L is a highly sensitive gamma radiation meter coupled with an extensively usable data logger. Measuring range of gamma radiation is seven orders from natural background. The applied special algorithm generates alarm in case of quick or slow significant increase of radiation level besides the two adjustable and fixed alarm thresholds. The device is designed to operate under extreme meteorological and mechanical conditions and suitable to be used for reconnaissance on vehicles and UAVs or planted for continuous automatic data collecting. Optional GPS and meteo sensors. Memory card is removeable from outside the device and can be connected to the evaluating computer by a data reader with USB port.

BGHRCS+32
gammatech.hu
Standard

Security and resilience — Protective security — Guidelines for the development of a security plan for an organization

This document gives guidance on developing and maintaining security plans. The security plan describes how an organization establishes effective security planning and how it can integrate security within organizational risk management practices. This document is applicable to all organizations regardless of type, size and nature, whether in the private, public or not-for-profit sectors, that wish to develop effective security plans in a consistent manner. This document is applicable to any organization intending to implement measures designed to protect their assets against malicious acts and mitigate their associated risks. This document does not provide specific criteria for identifying the need to implement or enhance prevention and protection measures against malicious acts. It does not apply to services and operations delivered by private security companies.

iso.org
Standard

CENCENELEC -- Societal and citizen security - Guidance for the security of hazardous materials (CBRNE) in healthcare facilities,2018

This Technical Specification provides guidance for managing security of (high risk) chemical, biological, radioactive, nuclear or Explosive materials, such as those covered by the EU CBRN action plan, that are used within healthcare facilities (HCF); it covers the lifecycle of such materials within a HCF’s span of control. In this Technical Specification these materials are referred to as ‘CBRNE materials’. It covers the protection of (high risk) CBRNE materials used in healthcare facilities against security threats relating to their deliberate misuse. It covers the protection of people, assets and information related to CBRNE materials. This Technical Specification also applies to circumstances where healthcare is provided at locations remote from the normal location of the HCF. This Technical Specification also provides guidance to all stakeholders that are responsible for each step in a lifecycle of CBRNE materials within the HCF such as such as administrator staff, facility management staff, logistics and transport staff, medical staff, waste management staff, domestic staff and security staff as well as visitors and contractors working on the HCF premises. This Technical Specification can be applied as part of generic management systems such as EN ISO 9001, EN ISO 22301, ISO 22320 and possibly ISO 28001. It does not apply to occupational health and safety issues deriving from the proper and improper use of such materials.

shop.standards.ie
Standard

IEC -- Radiation protection instrumentation - Equipment for measuring the activity concentration of gamma-emitting radionuclides in foodstuffs,2019

EC 61563:2019 applies to instruments used to measure the activity and/or activity concentration of gamma-emitting radionuclides in food and/or foodstuffs. This document applies to instruments used both as gross count type instruments and pulse height analysing type instruments used in field conditions and in measurement facilities. This document does not apply to high-resolution spectrometers that use germanium detectors. The instruments to which this document applies can be used to measure the activity and activity concentration of gamma-emitting radionuclides for a wide variety of samples, such as soil, sewage, plant, and animal life. The object of this document is to establish performance requirements, to provide test methods and to specify general characteristics, general test conditions, and radiological, environmental, mechanical and electromagnetic characteristics to be used to determine whether an instrument meets the requirements of this document. The test results provide information to end-users and manufacturers regarding the capability of instrument for reliable measurement of the activity and/or activity concentration of gamma-emitting radionuclides. This second edition cancels and replaces the first edition published in 2001. This edition includes the following significant technical changes with respect to the previous edition: a) The previous edition applied to handheld-type and portable-type instruments. This edition applies to transportable-type and installed-type instruments, as well as the scope of the previous edition. The handheld-type and portable-type instruments are mainly used in case of a post accidental situation, however, the transportable-type and installed-type instruments can be used through recovery phase. b) Uncertainty of measurement according to GUM is introduced. c) Detection limit defined in ISO 11929 is introduced to specify a minimum detectable activity. d) Environmental requirements, mechanical requirements and electromagnetic requirements are updated according to IEC 62706. e) Sample format of measuring report is introduced

webstore.iec.ch
Product / ServiceDetection, Identification and Monitoring (DIM)

SASS 2400

The SASS 2400 is our smallest wetted-wall aerosol particle collection system. It is designed to operate with a much lower air flow and fluid sample volume than the SASS 2300, while still employing the highly successful wetted-wall aerosol collection strategy that has received US Department of Homeland Security Certification under the US Safety Act of 2002. The cyclone used in the SASS 2400 operates at a 40 LPM air processing rate and requires only 1 ml of fluid, whereas the larger SASS 2300 processes 325 LPM of air and requires 4 to 5 ml of sample fluid. Water loss through evaporation is correspondingly reduced. Makeup water sources will last longer, or can be reduced in size. Extremely long collection periods continue to be a product highlight: Sample fluid is maintained at a constant amount independent of collection time, ambient air temperature, or relative humidity, providing unsurpassed monitoring capabilities in environments ranging from farmyards to hospitals to battlefields. SPECIFICATIONS Collection type Vial Consumables [AS] Water and vials Continuous operation [AS] Yes Decon? Yes Flow rate (lpm) 40 Particle size (_m) 1-10 Power requirement Internal battery and mains power supply Ruggedised? [AS] Yes Sample size (ml) 1 Sample technique Wet cyclone Sample time Variable Single unit? Yes Type of User First responders, Military and Health

ENFRIT+10
cbrneworld.com
Product / ServiceDetection, Identification and Monitoring (DIM)

BNS-97 Radiation Protection Monitor

BNS-97 RADIATION PROTECTION MONITOR PLACES OF APPLICATION Nuclear plants Isotope laboratories Environmental applications Waste yards PURPOSE OF MONITORING Continuous measurement and display of gamma dose-rate Area monitoring in system or stand-alone mode Local and central alarm signal management Event storage with RayMon software The improved version of BNS-97 is a highly sensitive gamma radiation meter and an alarm unit. Due to our patented invention the device measures radiation in a very wide range. BNS-97 is provided with the certification of the National Measurement Office of Hungary which is accredited by NAMAS (UK) for its use as authorized radiation protection device. The device alarms in case of significant increase of the radiation level both in short or long periods of time. The measured values appear locally on the LCD display of the device. BNS-97 alerts if the radiation level exceeds any of the three preset thresholds. The remote computer enables to create audible and visible alarm signals by parameter programming. In its basic configuration it is mounted with one single alarm unit, further alarm units are optional.

BGHRCS+32
gammatech.hu
Product / ServicePersonal Protective Equipment (including Collective Protection)

Quartz Children’s Gas Mask

Air Purifying Protective Respirator Kit For Infants & Children + Assistant Blower General Description The infant & Child Shield Hood is a respiratory protection system with a toy-like appeal, which is designed specifically to keep infants and children safe from airborne threats. The Infant & Child Shield Hood system is manufactured and tested in accordance with the specifications of the Israel Defense Forces and Ministry of Defense, and was provided to every newborn in Israel. Supreme protection: Hood-shaped for maximum seal and positive pressured. Provides a Protection Factor of 10,000. Powerful air-supply: Equipped with a 45 liter/minute blower for ample air supply (three times the amount breathable by a child). One-size fits all: Fits toddlers as well as children up to 10 years of age. User-friendly: Toy-like appeal, a wide visor for maximum field of vision, easy to don and doff, comfortable for prolonged use. Internal drinking mechanism: Allows baby formula feeding and liquid consumption via a drinking straw. Long shelf life: The system has a shelf life of 15 years in RT conditions (8 years).

EN
dekontacbrn.cz
Standard

ISO -- PPE ensembles for firefighters undertaking specific rescue activities Part 6: Footwear,2018

ISO 18639-6:2018 provides the principles that govern the development of incident type and/or hazard specific test methods and minimum performance requirements for safety footwear for firefighters while engaged in specific rescue activities. Footwear related to specific rescue activities, e.g. Road Traffic Crash, (RTC) and Urban Search and Rescue, (USAR) is documented in individual subclauses of this document. NOTE For further guidance refer ISO 18639‑1. The purpose of ISO 18639-6:2018 is to ensure minimum performance requirements for incident type and/or hazard specific safety footwear are designated. ISO 18639-6:2018 covers general footwear design, the minimum performance level of the materials used and the methods of test for determining this performance level. ISO 18639-6:2018 does not cover special footwear for use in other high risk situations such as structural firefighting. ISO 18639-6:2018 does not cover protection for the head, torso, arms, hands and legs or protection of the feet against other hazards, e.g. chemical, biological, radiation and electrical hazards, except for limited, accidental exposure to fire ground chemicals and contaminated blood or body fluids. Selection of the appropriate system of Personal Protective Equipment, (PPE), including footwear, is dependent on carrying out an effective risk assessment which identifies the hazard to be faced, evaluates the likelihood of those hazards and provides the means of reducing or eliminating these hazards.

iso.org
Product / ServiceIntegrated information management

HazResponse Incident Management for First Responders

Aimed at Incident Commanders, HazResponse® offers a complete risk-management software solution for proactively planning and preparing responses to CBRNe and Hazardous Material incidents. Key Features: HazResponse® provides: • A default set of Chemical, Biological, Radiological and Explosive calculations • The latest version of the Emergency Response Guide that is also used to produce Hazard templates • Map based display of the CBRNe situation and the possible assets at risk • Optional interface to Dispersion modelling • The ability to produce COMAH templates for accidental hazard releases • Modules for Sensor Integration and Language conversion Operationally Fielded A reliable and easy-to-use tool for blast and hazard calculations, HazResponse® allows co-ordination at all levels of response to speed up the decision-making process and assist with the tasking of emergency agencies. The software has been successfully used during the Commonwealth Games in the UK, the Olympic Games in Athens and the Asian Games in Qatar. More recently, HazResponse® was deployed in the 2012 London Olympics with the Multi-Agency Initial Incident Assessment Team (MAIAT) under the direction of Dorset Police at the Olympic sailing venue. Sensor Connectivity HazResponse® software is interoperable with the SCIM® application that can provide sensor data information to be used within the HazResponse® Incident message. The sensor data information can then be transferred or exported for the purpose of more detailed scientific evaluation and exploitation if provided within the overall response. The SCIM® application provides integration to more than 41 Sensor drivers. Complete Incident Management for CBRNe Using the incident management module the incident commander can register and display any points of interest on a map; such as Incident Control Point, track First Responder assets, etc. The application also allows operators to carry out detailed scene vulnerability assessments, planning of operations for the prioritization of evacuation and possible decontamination sites.

EN
bruhn-newtech.com
Standard

IEC -- Radiation protection instrumentation - Data format for radiation instruments used in the detection of illicit trafficking of radioactive materials,2012

IEC 62755:2012(E) provides a uniform format for data to be output from radiation measurement instruments for use in detection of illicit trafficking of radioactive materials. This enables interpretation of data without reference to manufacturer's documentation. This standard specifies the data format used for both required and optional data available at the output of radiation measurement instruments that are used for the detection of illicit trafficking of radioactive materials. The performance requirements for these types of radiation measurement instruments are described in other standards such as IEC 62401, IEC 62533, IEC 62694, IEC 62244, IEC 62327, IEC 62484, and IEC 62618.

webstore.iec.ch
Page 1 of 28